The hardware and bandwidth for this mirror is donated by METANET, the Webhosting and Full Service-Cloud Provider.
If you wish to report a bug, or if you are interested in having us mirror your free-software or open-source project, please feel free to contact us at mirror[@]metanet.ch.
ActivityIndex
package in R
The ActivityIndex package contains functions to 1) read raw accelerometry data and 2) compute “Activity Index” (AI) using the raw data. This introduction provides step-by-step instructions on how to read data from .csv
files and then compute AI.
The sample data were collected by accelerometer GT3X+ (ActiGraph, ), downloaded from . The data are available in the ActivityIndex package and their paths can be acquired using command:
system.file("extdata", "sample_GT3X+.csv.gz", package = "ActivityIndex")
system.file("extdata", "sample_table.csv.gz", package = "ActivityIndex")
sample_GT3X+.csv.gz
is the standard output of GT3X+ accelerometer, with a \(10\)-line header containing the basic information of the data collection, followed by \(3\)-column raw acceleration data. sample_table.csv.gz
contains the same \(3\)-column acceleration data without the \(10\)-line header. The first \(15\) lines of sample_GT3X+.csv.gz
are shown below:
## ------------ Data File Created By ActiGraph GT3X+ ActiLife v6.7.1 Firmware v2.5.0 date format M/d/yyyy at 30 Hz Filter Normal -----------
## Serial Number: NEO1DXXXXXXXX
## Start Time 10:54:00
## Start Date 6/27/2012
## Epoch Period (hh:mm:ss) 00:00:00
## Download Time 16:25:52
## Download Date 6/28/2012
## Current Memory Address: 0
## Current Battery Voltage: 4.22 Mode = 12
## --------------------------------------------------
## 0,0,0
## 0,0,0
## 0,0,0
## 0,0,0
## 0,0,0
while the first \(5\) lines of sample_table.csv.gz
are
## 0,0,0
## 0,0,0
## 0,0,0
## 0,0,0
## 0,0,0
Users should follow the same format while preparing their own data.
ReadGT3XPlus
and ReadTable
functions read the GT3X+ .csv.gz
file and the \(3\)-column acceleration table, respectively. To read the data, use the following code
sampleGT3XPlus = ReadGT3XPlus(system.file("extdata",
"sample_GT3X+.csv.gz", package = "ActivityIndex"))
sampleTable = ReadTable(system.file("extdata", "sample_table.csv.gz",
package = "ActivityIndex"))
Now that object sampleGT3XPlus
has class GT3XPlus
, which contains the raw data and header information. Function ReadGT3XPlus
automatically applies time stamps to the acceleration time series using the information from the header. For example, our sample data look like this
## List of 8
## $ SN : chr "NEO1DXXXXXXXX"
## $ StartTime : chr "10:54:00"
## $ StartDate : chr "2012-06-27"
## $ Epoch : chr "00:00:00"
## $ DownloadTime: chr "16:25:52"
## $ DownloadDate: chr "2012-06-28"
## $ Hertz : num 30
## $ Raw :Classes 'data.table' and 'data.frame': 1006080 obs. of 5 variables:
## ..$ Date: chr [1:1006080] "2012-06-27" "2012-06-27" "2012-06-27" "2012-06-27" ...
## ..$ Time: chr [1:1006080] "10:54:00" "10:54:00" "10:54:00" "10:54:00" ...
## ..$ X : num [1:1006080] 0 0 0 0 0 0 0 0 0 0 ...
## ..$ Y : num [1:1006080] 0 0 0 0 0 0 0 0 0 0 ...
## ..$ Z : num [1:1006080] 0 0 0 0 0 0 0 0 0 0 ...
## ..- attr(*, ".internal.selfref")=<externalptr>
## - attr(*, "class")= chr "GT3XPlus"
However, sampleTable
is much simpler, since limited information was given. The first \(6\) lines of it look like this
## Index X Y Z
## 1: 1 0 0 0
## 2: 2 0 0 0
## 3: 3 0 0 0
## 4: 4 0 0 0
## 5: 5 0 0 0
## 6: 6 0 0 0
AI is a metric to reflect the variability of the raw acceleration signals after removing systematic noise of the signals. Formally, its definition (a one-second AI) is
\[ \text{AI}^{\text{new}}_i(t;H)=\sqrt{\max\left(\frac{1}{3}\left\{\sum_{m=1}^{3}{\frac{\sigma^2_{im}(t;H)-\bar{\sigma}^2_{i}}{\bar{\sigma}^2_{i}}}\right\},0\right)},\label{EQ: AI} \] where \(\sigma^2_{im}(t;H)\) (\(m=1,2,3\)) is axis-\(m\)’s moving variance during the window starting from time \(t\) (of size \(H\)), and \(\bar{\sigma}_i\) is the systematic noise of the signal when the device is placed steady.
Function computeActivityIndex
is used to compute AI. The syntax of the function is
x
is the data used to compute AI. It can either be a GT3XPlus
object, or a \(4\)-column data frame (tri-axial acceleration time series with an index column). Either x_sigma0
or sigma0
are used to determine the systematic noise \(\bar{\sigma}_i\). More detailed example will follow to illustrate how to use them. epoch
is the epoch length (in second) of the AI. For example, the default epoch=1
yields to \(1\)-second AI, while minute-by-minute AI is given by epoch=60
. hertz
specifies the sample rate (in Hertz), which is usually \(10\), \(30\) or \(80\), etc.
We will continue our example of computing AI using our data sampleGT3XPlus
and sampleTable
.
According to the definition of the systematic noise \(\bar{\sigma}_i\), it changes with subject \(i\). Therefore, strictly speaking, we are to compute \(\bar{\sigma}_i\) every time we compute AI for a new subject \(i\). Argument x_sigma0
can be used to specify a \(4\)-column data frame (one column for indices and three columns for acceleration) which is used to calculate \(\bar{\sigma}_i\). The \(4\)-column data frame should contain the raw accelerometry data collected while the accelerometer is not worn or kept steady. For example, if we say a segment of our sample data (sampleTable[1004700:1005600,]
) meets such requirement, we could compute AI using the following code
Sometimes we do not want to calculate \(\bar{\sigma}_i\) whenever computing AI. For example, if \(10\) accelerometers were used to collect data over \(100\) subjects, there is no reason to calculate \(\bar{\sigma}_i\) for \(100\) times. One \(\bar{\sigma}_i\) is only needed for one accelerometer. Furthermore, if we could verify the \(\bar{\sigma}_i\)’s of the \(10\) accelerometers are close to each others, we could combine them into a single \(\bar{\sigma}=\sum_{i=1}^{10}{\bar{\sigma}_i}/10\). In this case, \(\bar{\sigma}\) will be used for all subjects in that study, which is crucial for fast processing of data collected by large studies.
This can be achieved by using the argument x_sigma0
to specify a pre-determined \(\bar{\sigma}_i\). Still using the same segment of data (sampleTable[1004700:1005600,]
) as an example, we calculate a sample_sigma0
beforehand with code
Then we could use this sample_sigma0
=\(0.00218\) to compute AI with code
Using either method to compute AI yield to the same result. The output of function computeActivityIndex
has two columns: RecordNo
saves the indices and AI
stores AI. The first \(10\) lines of AI_sampleGT3XPlus
is as follow
## Showing head and tail rows
## RecordNo AI
## 1 10:54:00 0.000
## 2 10:54:01 0.000
## 3 10:54:02 0.000
## 4 10:54:03 0.000
## 5 10:54:04 133.708
## 6 10:54:05 34.837
## RecordNo AI
## 5 10:54:04 133.708
## 6 10:54:05 34.837
## 7 10:54:06 62.947
## 8 10:54:07 54.207
## 9 10:54:08 124.708
## 10 10:54:09 147.842
We could also compute AI in different epoch. Say we want minute-by-minute AI, then we could use the following code
AI_sampleTable_min = computeActivityIndex(sampleTable,
sigma0 = sample_sigma0, epoch = 60, hertz = 30)
AI_sampleGT3XPlus_min = computeActivityIndex(sampleGT3XPlus,
sigma0 = sample_sigma0, epoch = 60, hertz = 30)
And according to the definition of AI, the minute-by-minute AI’s are simply the sum of all 1-second AI within each minute. The AI during the first \(6\) minutes are
## Showing head and tail rows
## RecordNo AI
## 1 10:54:00 3002.460
## 2 10:55:00 392.185
## 3 10:56:00 655.593
## 4 10:57:00 89.337
## 5 10:58:00 499.150
## 6 10:59:00 238.130
## RecordNo AI
## 1 10:54:00 3002.460
## 2 10:55:00 392.185
## 3 10:56:00 655.593
## 4 10:57:00 89.337
## 5 10:58:00 499.150
## 6 10:59:00 238.130
These binaries (installable software) and packages are in development.
They may not be fully stable and should be used with caution. We make no claims about them.