The hardware and bandwidth for this mirror is donated by METANET, the Webhosting and Full Service-Cloud Provider.
If you wish to report a bug, or if you are interested in having us mirror your free-software or open-source project, please feel free to contact us at mirror[@]metanet.ch.

Coding the Covid-19 Pandemic in Germany

In order to document the Covid-19 pandemic, a number of emergency codes were introduced in the course of 2020 and 2021. These are incorporated in the ICD10gm package, both as additions to the official 2020 and 2021 versions and by incorporating mid-year changes into the dataset. This vignette describes the usage of these codes with links to the official documentation mandating their use in Germany.

It should be noted that, in the ambulatory system in Germany, diagnoses are complemented by an additional flag denoting its status (G: secured, V: suspected, A: excluded, Z: condition following diagnosis). Regardless of formal coding rules, the presence of these flags should be considered when analysing German ambulatory data.

In 2020, there are differences between the ICD-10-GM and the WHO version (see WHO: Emergency use ICD codes for COVID-19 disease outbreak). For 2021, the ICD-10-GM largely followed the WHO version, leading to a number of code transitions.

This document is a work in progress.

Coding Guidelines

For the ambulatory sector, the National Association of Statutory Health Insurance Physicians (Kassenärztliche Bundesvereinigung, KBV) has released a guideline for Corona-related diagnoses:

In the ambulatory system, all codes must be accompanied by an additional flag for the diagnostic status (German: Zusatzzeichen für die Diagnosesicherheit). The KBV guidance states that, in general, only the flag “G” (German gesichert, English secured) should be used. There are however cases in which this flag can and should be used, see below.

Codes Relating to Acute infection

U07.1!: COVID-19 (virus identified)

Introduced on 13 February 2020, U07.1 codes Covid-19 cases confirmed by laboratory testing. Although a primary code in the WHO version of the ICD-10, it was included as a secondary code in the ICD-10-GM. This means that it should always be accompanied by a primary code denoting the manifestation (e.g. J06.9 or J12.8 for symptomatic patients; Z20.8 when testing contacts of confirmed cases).

The flag “A” (German Ausschluss, English excluded) can be used to denote that a test result was negative and occurs frequently in practice. The flag “Z” (German Zustand nach, English condition post diagnosis) may be used to denote that a prior infection has relevance for a subsequent treatment episode.

This code was carried through unchanged into the 2021 version of the ICD-10-GM.

17 February 2020: ICD-10 (WHO und GM): U07.1 kodiert COVID-19, Coronavirus-Krankheit-2019

U07.2!: COVID-19 (virus not identified)

This code was introduced on 23 Match 2020 to denote a “clinical epidemiological” diagnosis. It is used when Covid-19 is assumed but could not be confirmed by testing. For example, U07.2 was recommended when the corona test was negative or no test was available, but the patient had symptoms and contact with a confirmed case, or was associated with a cluster of viral pneumonia in a care home.

This code was carried through unchanged into the 2021 version of the ICD-10-GM.

23 March 2020: ICD-10 (WHO und GM): U07.2 kodiert Verdacht auf COVID-19

U99.0!: Test procedures for SARS-Cov-19

The code U99.0 denotes that a test for the SARS-CoV-2 virus was conducted. It does not indicate the result of the test. This is a secondary key and should usually be coded alongside the Z20.8 (“Contact with and exposure to other communicable diseases”). With asymptomatic testing, the appropriate code is Z11 (“Special screening examination for infectious and parasitic diseases”).

This code was carried through unchanged into the 2021 version of the ICD-10-GM.

25 May 2020: ICD-10-GM 2020: Neuer U-Kode U99.0! und neue Kodierfrage zu Testung auf SARS-CoV-2

Further information:

Codes Relating a Prior Infection

On 11 November 2020 (the middle of the second wave in Germany), three further codes were published:

ICD-10-GM 2020: Weitere neue U-Kodes im Zusammenhang mit COVID-19 publiziert

These codes differed from those introduced by the WHO. As a result, the codes were reallocated in the ICD-10-GM 2021 as follows:

ICD-10-GM 2021: Dateiaustausch wegen neuer Kodes U08-U10 im Zusammenhang mit COVID-19

These codes may be found alongside the primary code Z09.88 (“Follow-up examination”).

Codes Relating to Coronavirus Vaccination

On 11 March 2021, two codes relating to the Coronavirus vaccination programme were added:

These codes correspond to the official WHO version of the ICD-10.

In the ambulatory sector, the code U12.9 may be used alongside the flags “G” (German gesichert, English secured), “V” (German Verdacht auf, English suspected), “A” (German Ausschluss von, English excluded) or “Z” (German Zustand nach, English status following) to describe more precisely the nature of the (assumed) adverse effects.

ICD-10-GM 2021: Neue U-Kodes im Zusammenhang mit Impfungen gegen COVID-19 publiziert

Codes Relating to Covid-19 Symptoms and Sequalae

In addition to the newly-introduced codes, physicians may choose to use existing codes to document the symptoms of Covid-19. Examples include:

As post covid syndrome (U09.9!) is a secondary code, it should be accompanied by a primary code specifying the nature of the complaint. In practice, this may be a symptom, a disease resulting from the infection, or a code relating to a functional or psychiatric condition, for example:

These binaries (installable software) and packages are in development.
They may not be fully stable and should be used with caution. We make no claims about them.