The hardware and bandwidth for this mirror is donated by METANET, the Webhosting and Full Service-Cloud Provider.
If you wish to report a bug, or if you are interested in having us mirror your free-software or open-source project, please feel free to contact us at mirror[@]metanet.ch.
Regimens are defined using the new_regimen()
function.
You should provide information on the dose amount, how many doses, and
the dosing interval. However, how you provide that information is very
flexible. You can e.g. specify:
which will administer 5 doses of 100 mg (or whatever the unit is), at an interval of 12 hours. The same can however also be specified as:
or:
Be careful: if the length of the amt
vector is not the
same as the length in times
, the function will repeat the
first amt
specified. The same goes for the arguments
type
, cmt
, and t_inf
.
By default, the new_regimen()
function assumes the dose
is given as bolus. If you want to specify that these should be given as
infusion, specify the type
and t_inf
arguments:
reg1 <- new_regimen(
amt = 100,
times = c(0, 12, 24, 36, 48),
type = "infusion",
t_inf = c(1, 1, 1.5, 1.5, 1)
)
When you created the model using new_ode_model
, you also
specified a default dosing compartment. If you didn’t specify the
dose
argument, the default dosing compartment is 1. Now,
should you want to administer the dose into a different compartment, you
can override it with the cmt
argument:
Which will administer the doses to compartments 1, 1, 2, 2, and 3, respectively (of course this is a hypothetical example).
Note: PKPDsim
doesn’t care about what unit the dose
is in, you have to define this yourself in conjunction with the model
code and observation scale.
Instead of simulating the full concentration time course for a give
model, if you want to simulate the PK(PD) at steady state, you can also
specify the ss=TRUE
argument to new_regimen()
,
which will then simulate the regimen at steady state. By default, steady
state is assumed to occur after 5 days (PKPDsim doesn’t check if steady
state is reached!), but if you want to decrease or increase this you can
do so by specifying the n_ss
argument which takes the
number of doses to simulate before assuming steady state.
## Note: Steady state regimen, steady state assumed to be reached at t = 0.
## t type amt t_inf
## 1 0 bolus 100 0
## 2 12 bolus 100 0
## 3 24 bolus 100 0
## 4 36 bolus 100 0
## 5 48 bolus 100 0
These binaries (installable software) and packages are in development.
They may not be fully stable and should be used with caution. We make no claims about them.