The hardware and bandwidth for this mirror is donated by METANET, the Webhosting and Full Service-Cloud Provider.
If you wish to report a bug, or if you are interested in having us mirror your free-software or open-source project, please feel free to contact us at mirror[@]metanet.ch.

Introduction to STICr

The goal of STICr (pronounced “sticker”) is to provide a standardized set of functions for working with data from Stream Temperature, Intermittency, and Conductivity (STIC) loggers, first described in Chapin et al. (2014). STICs and other intermittency sensors are becoming more popular, but their raw data output is not in a form that allows for convenient analysis. In this vignette, we will walk through some typical processing steps, starting from the raw STIC model output and ending with classified and visualized STIC data.

Let’s get going - load STICr!

# install.packages("STICr")  # if needed: install package from CRAN
# devtools::install_github("HEAL-KGS/STICr") # if needed: install dev version from GitHub
library(STICr)

Tidying raw STIC data

STICs are created from modified HOBO Pendant loggers (see instructions for how to do this here), and as a result the raw data downloaded from the STIC logger comes in a proprietary .hobo format. Before using STICr, you must use the HOBOware software to export the STIC output data as a CSV file. STICr can then use tidy_hobo_data() to get this into an R-friendly tidy format. We will also use the convert_utc argument to ensure that the data are converted from local time to UTC.

# use tidy_hobo_data to load and tidy your raw HOBO data
df_tidy <-
  tidy_hobo_data(
    infile = "https://samzipper.com/data/raw_hobo_data.csv",
    outfile = FALSE, convert_utc = TRUE
  )

head(df_tidy)
#>              datetime condUncal  tempC
#> 1 2021-07-16 22:00:00   88178.4 27.764
#> 2 2021-07-16 22:15:00   77156.1 28.655
#> 3 2021-07-16 22:30:00   74400.5 28.060
#> 4 2021-07-16 22:45:00   74400.5 27.764
#> 5 2021-07-16 23:00:00   74400.5 27.862
#> 6 2021-07-16 23:15:00   71644.9 27.370

The output of tidy_hobo_data() is a data frame with 3 columns:

Calibrating STIC data

Since the raw STIC data is in a sensor-specific relative conductivity value, it can often be useful to calibrate STIC loggers. This involves taking STIC readings in the lab with the sensor immersed in standards with known specific conductivity - detailed instructions for how to do this can be found here.. STICr can then use the get_calibration() and apply_calibration() functions to take these lab standard measurements and apply them to the STIC sensor output data.

# inspect the example calibration standard data provided with the package
data(calibration_standard_data)
head(calibration_standard_data)
#> # A tibble: 4 × 3
#>     sensor standard condUncal
#>      <dbl>    <dbl>     <dbl>
#> 1 20946471      100    12400.
#> 2 20946471      250    23422.
#> 3 20946471      500    46845.
#> 4 20946471     1000   104712.

The calibration standard data has three columns:

Using this calibration standard data, we can then create a calibration curve using the get_calibration() function and apply it to our data using the apply_calibration() function. Currently, get_calibration() only allows for a linear calibration curve.

# get calibration
lm_calibration <- get_calibration(calibration_standard_data)
summary(lm_calibration)
#> 
#> Call:
#> lm(formula = standard ~ condUncal, data = calibration_data)
#> 
#> Residuals:
#>      1      2      3      4 
#> -33.43  11.27  37.50 -15.34 
#> 
#> Coefficients:
#>              Estimate Std. Error t value Pr(>|t|)   
#> (Intercept) 1.496e+01  3.136e+01   0.477   0.6803   
#> condUncal   9.554e-03  5.328e-04  17.932   0.0031 **
#> ---
#> Signif. codes:  0 '***' 0.001 '**' 0.01 '*' 0.05 '.' 0.1 ' ' 1
#> 
#> Residual standard error: 37.99 on 2 degrees of freedom
#> Multiple R-squared:  0.9938, Adjusted R-squared:  0.9907 
#> F-statistic: 321.5 on 1 and 2 DF,  p-value: 0.003096

This sensor has a very strong calibration, with an R^2 > 0.99. We can now apply this to the tidied STIC data we loaded earlier. We will use the outside_range_flag argument to flag any data points that are outside the range of the standards used to develop the calibration curve, as these should be treated with caution.

# apply calibration
df_calibrated <- apply_calibration(
  stic_data = df_tidy,
  calibration = lm_calibration,
  outside_std_range_flag = T
)

head(df_calibrated)
#>              datetime condUncal  tempC      SpC outside_std_range
#> 1 2021-07-16 22:00:00   88178.4 27.764 857.3845                  
#> 2 2021-07-16 22:15:00   77156.1 28.655 752.0820                  
#> 3 2021-07-16 22:30:00   74400.5 28.060 725.7561                  
#> 4 2021-07-16 22:45:00   74400.5 27.764 725.7561                  
#> 5 2021-07-16 23:00:00   74400.5 27.862 725.7561                  
#> 6 2021-07-16 23:15:00   71644.9 27.370 699.4302

We now have two additional columns in our STIC data frame:

Classify the data

Many people use STIC sensors to monitor when a stream is wet or dry, based on the principle that the conductivity of water is much higher than that of air. Therefore, high values of condUncal and/or SpC can be classified as wet conditions, and low values can be classified as dry conditions. In STICr, this can be done using the classify_wetdry() function, but this requires determining a suitable threshold to use for differentiating wet and dry conditions from the STIC data. It is typically useful to plot the data to determine this threshold.

# plot SpC as a timeseries and histogram
plot(df_calibrated$datetime, df_calibrated$SpC, xlab = "Datetime", ylab = "SpC", main = "Specific Conductivity Timeseries")

hist(df_calibrated$SpC, xlab = "Specific Conductivity", breaks = seq(0, 1025, 25), main = "Specific Conductivity Distribution")

It can be unclear when exactly the sensor is wet or dry, particularly if the sensor has been buried by deposited sediments (which have an intermediate conductivity between water and air). In this case, there is a clear abundance of points with SpC < 100, which we will use for our classification threshold.

# classify data
df_classified <- classify_wetdry(
  stic_data = df_calibrated,
  classify_var = "SpC",
  threshold = 100,
  method = "absolute"
)
head(df_classified)
#>              datetime condUncal  tempC      SpC outside_std_range wetdry
#> 1 2021-07-16 22:00:00   88178.4 27.764 857.3845                      wet
#> 2 2021-07-16 22:15:00   77156.1 28.655 752.0820                      wet
#> 3 2021-07-16 22:30:00   74400.5 28.060 725.7561                      wet
#> 4 2021-07-16 22:45:00   74400.5 27.764 725.7561                      wet
#> 5 2021-07-16 23:00:00   74400.5 27.862 725.7561                      wet
#> 6 2021-07-16 23:15:00   71644.9 27.370 699.4302                      wet

We now have a new column, wetdry, which reads “wet” when SpC exceeds the threshold and “dry” when SpC is less than the threshold. We can plot and visualize the classified data.

# plot SpC through time, colored by wetdry
plot(df_classified$datetime, df_classified$SpC,
  col = as.factor(df_classified$wetdry),
  pch = 16,
  lty = 2,
  xlab = "Datetime",
  ylab = "Specific conductivity"
)
legend("topright", c("dry", "wet"),
  fill = c("black", "red"), cex = 0.75
)

QAQC data

STICr has built-in a built-in QAQC function, qaqc_stic_data(), to deal with some common data issues we have experienced. This function requires classified STIC data, such as that output by classify_stic_data(), and produces a QAQC column or columns which could include the following data flags:

If concatenate_flags = T, these flags will be combined into a single column named QAQC; if not, they will be separate columns. A blank

# apply qaqc function
df_qaqc <-
  qaqc_stic_data(
    stic_data = df_classified,
    spc_neg_correction = T,
    inspect_classification = T,
    anomaly_size = 2,
    window_size = 96,
    concatenate_flags = T
  )
head(df_qaqc)
#>              datetime condUncal  tempC      SpC wetdry QAQC
#> 1 2021-07-16 22:00:00   88178.4 27.764 857.3845    wet     
#> 2 2021-07-16 22:15:00   77156.1 28.655 752.0820    wet     
#> 3 2021-07-16 22:30:00   74400.5 28.060 725.7561    wet     
#> 4 2021-07-16 22:45:00   74400.5 27.764 725.7561    wet     
#> 5 2021-07-16 23:00:00   74400.5 27.862 725.7561    wet     
#> 6 2021-07-16 23:15:00   71644.9 27.370 699.4302    wet
table(df_qaqc$QAQC)
#> 
#>      DO   O 
#> 916   1  83

We can see that there was 1 “D” flag for a potential deviation (a dry reading surrounding by wet readings) and 83 “O” points indicating the calibrated SpC was outside the range of the standards used for calibration.

Because we set concatenate_flags = T, we now have a single column, QAQC that combines all flags. Using table, we can inspect the total number of data flags in our classified dataset.

These binaries (installable software) and packages are in development.