actibase Package

actibase is a baseline package for raw actigraphy and activity workflows. It provides readers and core preprocessing helpers that downstream packages can build on, such as step-count or summarization overlays.

Installation

You can install actibase from GitHub with:

# install.packages("remotes")
remotes::install_github("jhuwit/actibase")

Quick start

library(actibase)
res = acti_standardize_data(acti_raw_data)
resampled = acti_resample(res, sample_rate = 30L)

What lives here

actibase keeps the primitives that other packages can build on:

Device-limit helpers distinguish adjacent samples from sustained runs: acti_flag_adjacent_device_limit_samples() marks near-limit samples with a neighboring limit sample, while acti_flag_contiguous_device_limit_runs() marks axis- and sign-specific runs meeting min_length. The older function names remain available for compatibility.

The flag functions label questionable raw samples and intervals; they do not replace vendor readers, wear/nonwear algorithms, or activity summaries. acti_flag_cdc_labels() is syntactic sugar for attaching CDC letter codes to flag columns already computed, so raw-data checks can be compared with NHANES.

Higher-level summarization, step-count mapping, and downstream analysis should live in overlay packages.

NHANES PAM flag mapping

The table maps the CDC NHANES PAM minute flags to the general-purpose sample-level or window-level helpers in actibase. The functions do not reproduce CDC’s data pipeline automatically: use the CDC thresholds and window rules when matching NHANES output. Flags with axis-specific output need by_axis = TRUE where that option is available. acti_flag_cdc_labels() can combine the resulting logical columns into CDC-style letter strings.

CDC code CDC definition (summary) actibase function and output Match notes
A–C Axis-specific spikes: adjacent-sample change ≥11 g acti_flag_spike(by_axis = TRUE): flag_spike_X/Y/Z Sample-level; set spike_size = 11 and use the appropriate sampling rate.
D–F Per-minute count of positive near-limit values, ≥690 samples acti_flag_device_limit_windows(): flag_device_max_X/Y/Z Set min_count = 690, window_seconds = 60, dynamic_range = c(-6, 6), and epsilon = 0.05.
G–I Per-minute count of negative near-limit values, ≥690 samples acti_flag_device_limit_windows(): flag_device_min_X/Y/Z Same thresholds as D–F, for negative values.
J–L Contiguous positive near-limit run, ≥160 samples acti_flag_contiguous_device_limit_runs(): flag_contiguous_max_X/Y/Z Set min_length = 160; CDC also assigns the run to every overlapping minute.
M–O Contiguous negative near-limit run, ≥160 samples acti_flag_contiguous_device_limit_runs(): flag_contiguous_min_X/Y/Z Set min_length = 160; CDC permits runs to cross minute boundaries.
P Contiguous impossible gravity values acti_flag_impossible(): flag_impossible Generalized thresholds are configurable; CDC uses seven samples, <0.01 g change on each axis, vector magnitude >1.25 g, excluding ±6 g values.
Q Contiguous adjacent zero values acti_flag_all_zero(): flag_all_zero Package checks all three axes. CDC documents a historical programming error that checked only X; exact reproduction of that error is not intended.
R Contiguous identical, non-zero three-axis samples acti_flag_repeated_samples(): flag_repeated_samples Configure min_length = 2, exclude_zero = TRUE, require_equal_axes = TRUE. CDC’s reported run length/minute attribution may differ.
S–U Axis-specific 1-second spike counts acti_flag_spike_second(by_axis = TRUE): flag_spike_second_X/Y/Z Set window_seconds = 1, min_spikes = 13, spike_size = 11; CDC counts qualifying local-extremum events.
V Minute before and after an invalid minute acti_flag_adjacent_invalid_periods(): flag_adjacent_invalid Caller supplies invalid periods; CDC’s hour-boundary exception requires matching group boundaries.
W–Y Axis-specific interval jumps within a second acti_flag_interval_jump(by_axis = TRUE): flag_interval_jump_X/Y/Z Set window_seconds = 1, min_repeats = 10, min_distinct = 3, min_separation = 0.5; implementation is an approximation of the CDC interval-jump rule.

Letter labels are made from columns already present in the data; the helper does not run detectors or infer missing axis-specific results:

raw <- acti_flag_spike(raw, by_axis = TRUE)
raw <- acti_flag_device_limit_windows(raw, dynamic_range = c(-6, 6),
                                      min_count = 690)
raw <- acti_flag_contiguous_device_limit_runs(raw, dynamic_range = c(-6, 6),
                                              min_length = 160)
raw <- acti_flag_cdc_labels(raw)

Funding

This work was supported by NIH P30AG021334 and the Johns Hopkins Older Americans Independence Center (OAIC) Pepper Center grant.

These binaries (installable software) and packages are in development.
They may not be fully stable and should be used with caution. We make no claims about them.