title: "Memory-based charts: EWMA and CUSUM"
output: rmarkdown::html_vignette
vignette: >
  %\VignetteIndexEntry{Memory-based charts: EWMA and CUSUM}
  %\VignetteEngine{knitr::rmarkdown}
  %\VignetteEncoding{UTF-8}
---

```{r, include = FALSE}
knitr::opts_chunk$set(collapse = TRUE, comment = "#>",
                      fig.width = 7, fig.height = 4.2)
```

```{r setup, message = FALSE}
library(shewhartr)
library(ggplot2)
library(dplyr)
```

## When the Shewhart chart is too slow

A Shewhart chart looks at one observation at a time. Each point is
compared against the centre line and the 3-sigma limits, and that's
it — the chart has *no memory* of what came before (the runs rules
add a little, but only a little). This makes Shewhart charts excellent
at catching **large** shifts the moment they happen, but fairly slow
at catching **small persistent** shifts that would only become
visible after the data has had time to drift.

EWMA and CUSUM accumulate information across observations, trading a
slightly less direct interpretation for substantially better
sensitivity to small shifts.

```{r}
# A 0.5-sigma sustained shift after observation 40
set.seed(2026)
n      <- 80
shift  <- c(rnorm(40, mean = 0, sd = 1),
            rnorm(40, mean = 0.5, sd = 1))
df     <- tibble::tibble(t = seq_len(n), y = shift)

imr  <- shewhart_i_mr(df,  value = y, index = t)
ewma <- shewhart_ewma(df,  value = y, index = t)
cusum <- shewhart_cusum(df, value = y, index = t)

# Position of the first alarm under each chart
first_alarm <- function(fit) {
  hits <- which(fit$augmented$.flag_any)
  if (length(hits) == 0L) NA_integer_ else min(hits)
}
tibble::tibble(
  chart  = c("I-MR", "EWMA", "CUSUM"),
  alarm  = c(first_alarm(imr), first_alarm(ewma), first_alarm(cusum))
)
```

For a 0.5-sigma shift, the I-MR chart often fails to signal at all
within 80 observations, while the EWMA and CUSUM typically catch it
within a few points of the change.

## EWMA — Exponentially Weighted Moving Average

The EWMA statistic is a recursive convex combination:
$$z_i = \lambda x_i + (1 - \lambda) z_{i-1}, \qquad z_0 = \mu.$$

With `lambda` close to 1 the chart behaves like a Shewhart I chart
(little memory). With `lambda` close to 0 it averages over a long
history (heavy memory, slow but very sensitive). The classical
default `lambda = 0.2`, `L = 2.7` gives `ARL_0 ≈ 370` and is well
matched to detecting shifts of 0.5 to 1 sigma (Lucas & Saccucci 1990).

```{r}
fit <- shewhart_ewma(df, value = y, index = t,
                     lambda = 0.2, L = 2.7)
fit
autoplot(fit)
```

The control limits in an EWMA chart are **time-varying** by default.
They start narrow and widen out to the asymptotic value
`L · σ · sqrt(λ / (2 - λ))` as the recursion warms up. This is the
correct probability-symmetric calibration; setting
`steady_state = TRUE` flattens them out at the asymptotic value (a
common simplification once you have a long enough baseline).

```{r}
shewhart_ewma(df, value = y, index = t, steady_state = TRUE) |>
  autoplot()
```

### Choosing `lambda`

A practical guide (Montgomery 2019, Table 9.10):

| Target shift size | Reasonable `lambda` | `L` | ARL_0 |
|-------------------|---------------------|-----|-------|
| 0.25 σ            | 0.05                | 2.49 | ~370  |
| 0.50 σ            | 0.10                | 2.70 | ~370  |
| 0.75 σ            | 0.20                | 2.86 | ~370  |
| 1.00 σ            | 0.40                | 3.00 | ~370  |

Choose the *smallest* shift you care about, then use the matching row.
You can validate the actual ARL with [`shewhart_arl()`] from the
arl-simulation vignette.

## CUSUM — Cumulative Sum

The tabular CUSUM keeps two non-negative running totals, one for
upward drift and one for downward drift:

$$
C^+_i = \max\!\left(0,\; C^+_{i-1} + (x_i - \mu) - k\sigma\right)
$$

$$
C^-_i = \max\!\left(0,\; C^-_{i-1} - (x_i - \mu) - k\sigma\right)
$$

An alarm fires when either crosses the **decision interval**
`h · sigma`. The reference value `k` is typically *half* the smallest
shift size the chart should be sensitive to (so `k = 0.5` for shifts
of `1·σ`); `h` controls the false-alarm rate.

```{r}
fit <- shewhart_cusum(df, value = y, index = t, k = 0.5, h = 4)
fit
autoplot(fit)
```

The plot draws `C+` as positive bars (potential upward drift) and
`C-` as negative bars (potential downward drift), with the symmetric
decision interval in dashed red. CUSUM's main charm is interpretability
once it signals: the bar's height tells you how much accumulated
deviation triggered the alarm.

### Choosing `k` and `h`

Hawkins & Olwell (1998), Table 3.1, gives ARL profiles for
`k = 0.5` (the most common choice):

| `h`   | ARL_0 (in control) | ARL_1 at 1σ shift |
|-------|--------------------|---------------------|
| 4.00  | ~168               | ~8.4                |
| 4.77  | ~370               | ~10.4               |
| 5.00  | ~465               | ~10.9               |

The default `h = 4` is appropriate for diagnostic monitoring. For a
production chart matched to the typical Shewhart `ARL_0 = 370`, raise
`h` to `4.77`.

## Phase II monitoring

Both charts accept `target` and `sigma` to override the in-data
estimates — exactly what you need for Phase II monitoring against a
clean Phase I baseline. The example below calibrates on a 60-point
in-control baseline and then monitors a fresh 40-point period:

```{r}
set.seed(1)
baseline <- tibble::tibble(t = 1:60, y = rnorm(60, mean = 100, sd = 2))
mu_hat   <- mean(baseline$y)
sd_hat   <- sd(baseline$y)

new_data <- tibble::tibble(
  t = 61:100,
  y = rnorm(40, mean = 100.8, sd = 2)   # 0.4 sigma shift
)

shewhart_ewma(new_data, value = y, index = t,
              target = mu_hat, sigma = sd_hat,
              lambda = 0.2, L = 2.7) |>
  autoplot()
```

A `calibrate()` / `monitor()` integration for memory-based charts is
on the roadmap for a future release; for the moment the explicit
`target` / `sigma` arguments give you the same workflow with one
extra line.

## Which one should I use?

| Question                                          | EWMA            | CUSUM           | Shewhart        |
|---------------------------------------------------|-----------------|-----------------|-----------------|
| Best at 0.25–1 σ shifts?                          | ✔               | ✔               |                 |
| Best at >2 σ shifts?                              |                 |                 | ✔               |
| Plot reads like the original variable?            | ✔               |                 | ✔               |
| Communicates *magnitude* of accumulated drift?    |                 | ✔               |                 |
| Survives autocorrelated data well?                | (with care)     | (with care)     |                 |
| Pairs naturally with runs rules?                  | (Nelson 1 only) |                 | ✔               |

Many practitioners run **both** a Shewhart chart and an EWMA (or
CUSUM) on the same series — the Shewhart catches large excursions,
the memory-based catches the slow drifts.

## References

* Roberts, S. W. (1959). Control Chart Tests Based on Geometric
  Moving Averages. *Technometrics*, 1(3), 239-250.
* Page, E. S. (1954). Continuous Inspection Schemes. *Biometrika*,
  41(1-2), 100-115.
* Lucas, J. M., & Saccucci, M. S. (1990). Exponentially Weighted
  Moving Average Control Schemes: Properties and Enhancements.
  *Technometrics*, 32(1), 1-12.
* Hawkins, D. M., & Olwell, D. H. (1998). *Cumulative Sum Charts and
  Charting for Quality Improvement*. Springer.
* Montgomery, D. C. (2019). *Introduction to Statistical Quality
  Control* (8th ed.). Wiley. Chapter 9.