The hardware and bandwidth for this mirror is donated by METANET, the Webhosting and Full Service-Cloud Provider.
If you wish to report a bug, or if you are interested in having us mirror your free-software or open-source project, please feel free to contact us at mirror[@]metanet.ch.
spant 2.24.0
- Added argument to adjust the legend font size in ortho3
function.
- Improved metabolite simulation performance thanks to the expm
package recently adding support for complex matrices.
spant 2.23.0
- abfit options for lipid and MM maximum broadening and maximum
frequency shift now default to be the same as the metabolite values
unless explicitly changed.
- Added function to calculate the correlation matrix from a
basis_set.
- Fix for RDA files where a comma is sometimes used as a decimal
point.
spant 2.22.0
- Added find_bids_mrs and mrs_data2bids helper functions.
- Improved handling of CMRR semi-LASER SVS water reference scans.
- Added functions for GLS coil combination.
spant 2.21.0
- Fixed compiler warnings for Fortran code.
- Added glm_spec function.
- Added add_noise_spec_snr function.
spant 2.20.0
- Added vertical line colour and linetype options for stackplots.
- Added option to give Y axis labels in units of seconds for
spectrograms.
spant 2.19.0
- Removed dependency on smoother package.
- Added functions for generating BOLD and trapezoidal response
shapes.
spant 2.18.0
- Improved automated file type detection.
- Bug fixes for DICOM MRS reader.
- scale_spec function now works with basis set objects.
- Added invert_fit option to plotting methods.
spant 2.17.0
- Simulation duration output is now rounded to 2dp.
- sim_basis now accepts a character vector of molecular names.
- Added get_1h_brain_basis_names function.
spant 2.16.0
- Added subset option to mean_dyns function.
- Added vline option to plot.
- Added common 31P brain metabolites.
- Added verbose option to sim_basis.
spant 2.15.0
- An SNR estimate of zero in comb_coils is now a failure case.
- Bug fix for GE pfile reader header revision 20.
- Added a function for finding valid MRS files : find_mrs_files.
spant 2.14.0
- Added vline argument to stackplot function.
- Added functions to set MRS data TR and number of transients.
spant 2.13.0
- Improved defaults for sim_brain_1h function.
- Added scale_basis_amp function.
- Added crop_basis function.
spant 2.12.0
- Amplitude scaling functions duplicate water reference amplitudes
when sensible.
- Added hline option to the mrs_data plot function.
spant 2.11.0
- Bug fix for Siemens RDA slice thickness detection.
- ProtocolName is now read from GE p-files.
spant 2.10.0
- Tentative support for UIH DICOM MRS format.
- Improved support for reading GE p-files.
- Added a WIP function to export a one-page summary pdf of the fit
result “one_page_pdf”.
spant 2.9.0
- Bug fix when using align function with masked data.
- mean_dyn_blocks returns the input data when block_size is set to
1.
spant 2.7.0
- Added Manufacturer tag to metadata.
- Added mask_xy_corners and mask_xy_ellipse functions.
- Added functions to fit T1 and T2 relaxation curves.
- Updated CI checks.
spant 2.6.0
- Masked spectra plotted with image are now shown with a value of
zero.
- Added function to read .pta files - read_pulse_pta.
- Added a function to make basis set objects from a directory of
LCModel formatted RAW files - make_basis_from_raw.
- Added horizontal line to fit result plots.
- Improvements to reading LCM .raw files with variable numerical
columns.
spant 2.5.0
- Improved function documentation for water concentration
scaling.
- Added water and tCr scaling examples to the introduction
vignette.
- Better error checking for reading ima files.
- read_basis function improved to work with variable formatting.
- Improved default method of time-domain signal amplitude
estimation.
- Added helper functions for working with basis set objects:
scale_basis_from_singlet, resample_basis and get_basis_subset.
- Bug fix for STEAM basis simulation being incorrectly scaled for
internal water scaling methods.
spant 2.4.0
- Performance improvement for reading VD format TWIX files.
- Function added to scale all metabolite levels by a set value
(scale_amp_ratio_value).
spant 2.3.0
- Verbose option added to read_ima_coil_dir and read_ima_dyn_dir
functions.
- Support added for reading jMRUI txt formatted MRS data.
- sim_brain_1h default sequence changed to semi-LASER and
line-broadening option added.
- Bug fix for reading LCModel RAW files.
- Bug fix for HSVD filter when only 0 or 1 components are found in the
filter region.
- Improved removal of unwanted data points for reading TWIX formatted
data.
- A json sidecar is automatically written when exporting NIfTI MRS
formatted data.
- TWIX reader improved to only read data points from the last scan in
the file. This also fixes a rare bug.
spant 2.2.0
- peak_info function now works with masked datasets.
- Bug fix for HSVD function not working with frequency domain
data.
- Bug fix for TWIX affine calculation when not using power of two
matrix dimensions.
- New function (crop_td_pts_pot) to round a dataset length down to the
nearest power of 2.
- Added ret_metab_only option to comb_coils.
- rats now only returns the corrected data by default, note this could
break old code.
spant 2.1.0
- y-axis label can now be changed with a new argument (yaxis_lab) to
plot.mrs_data.
- Segmentation files are now checked for non-integer values.
- gridplot has better row and col number defaults for MRSI, and has a
bug fix for plotting masked spectra.
- Updated functions for dealing with lists of MRSI datasets.
- Bug fix for crop_xy function when working with odd matrix
sizes.
spant 2.0.0
- magrittr pipe (%>%) is no longer loaded together with spant now
the base pipe is part of R. Vignettes and tests have been updated to use
the base pipe.
- NIfTI MRS writer no longer fails when dealing with a NULL affine
matrix.
- Bug fix for NIfTI MRS writer, where frequency domain data was not
correctly converted to time-domain before export.
spant 1.22.0
- Added MSM and acetone to the set of internally defined
molecules.
- write_mrs_nifti function removed from userspace. write_mrs should be
used instead.
- set_td_pts and crop_td_pts now work with lists of spectra.
- Multiple files can now be written by passing a list of spectra to
write_mrs.
spant 1.21.0
- Bug fix for get_mrsi_voi function due to incorrect rounding of MRSI
matrix dimensions in some cases.
- Added mask_fit_res function.
- Option added to get_2d_psf function to ensure odd output
dimensions.
- Bug fix for using rats on datasets with masked voxels.
- Added spec_decomp function.
- Added ret_scale_factor option to scale_spec function.
spant 1.20.0
- Options added to ft_dyns to return the modulus of the 2D spectra and
to pre-transform the chemical shift axis if needed.
- Bug fix for printing lists of mrs_data objects.
- comb_coils function now supports lists of mrs_data objects.
- IMA reader now respects the verbose option in read_mrs.
- Bug fix for get_mrsi_voi ignoring the ker argument.
- Bug fix for reading Siemens TWIX files.
spant 1.19.0
- Added sum_mrs_list function.
- Bug fix for operating on mrs_data with single values that aren’t
numeric types. For example, multiplying mrs_data by a single complex
number now works.
- A number of common preprocessing functions now operate on lists of
mrs_data objects.
- Change to NIfTI MRS reader to fix a failing test when using the
development version of RNifti.
spant 1.18.0
- Better behaviour when using stackplot with single spectra
datasets.
- Better behaviour when using image with single spectra datasets.
- Bug fix for reading MEGA-PRESS data in TWIX format.
- Better error checking for lists of spectra.
- Bug fix for calculating NAA linewidth from MEGA-PRESS data.
spant 1.17.0
- New function added (recon_twix_2d) for reconstructing basic phase
encoded twix 2D MRSI data.
- File name argument for read_mrs now permits globbing, eg
read_mrs(“*.dcm”).
- Improved plotting of metabolite maps containing infinite
values.
- Improvements to GE p-file reader.
- Bug fix for TWIX MRSI voxel dimensions.
- get_mrsi2d_seg now returns partial volume maps as well as a data
frame.
- Improved error handling for spec_op function.
- apodise_xy can now be applied to multi-coil and dynamic
datasets.
spant 1.16.0
- The package has been published in the Journal for Open Source
Software : “spant: An R package for magnetic resonance spectroscopy
analysis. JOSS 2021, 6(67), 3646”.
- The basis result of the HSVD function is now an mrs_data
object.
- The complete model signal is now output by the HSVD function.
- image function x-axis updated to be consistent with other plotting
methods.
- Minor refactor of the simulation code and a dependency swap from
complexplus to exmp packages.
spant 1.15.0
- Added a unit test for reading and writing LCM .basis formatted
files.
- Added FWHM estimates for tCr and tCho in ABfit.
- Added water suppression efficiency and water FWHM measures to the
diagnostic output of svs_1h_brain_analysis.
- Added get_head_dyns and get_tail_dyns to return the first and last
dynamic scans within a dataset.
- Fixed CI errors.
- Improved installation instructions.
- Removed comb_csv_results function and reduced the number of required
packages.
spant 1.14.0
- Added glycerol simulation parameters,
e.g. get_mol_paras(“glyc”).
- Bug fix for read_ima_* functions.
- Improved y = 0 baseline for stackplot when setting bl_lty
parameter.
- Removed norm_mrs function and replaced with scale_spec for simple
data scaling tasks, eg scaling based on the integration of a spectral
region.
- Added spec_op function for performing simple summary operations on
spectral segments.
- Changed the name of scale_mrs function to scale_mrs_amp.
- Added mean_mrs_list function.
- Improved LCM RAW and BASIS readers (contribution from Alex
Craven).
spant 1.13.0
- ABfit frequency shifts limits are now specified in ppm rather than
Hz to improve consistency between field strengths.
- NAA linewidth is now estimated and output by ABfit when NAAG is
absent - useful for BRAINO phantom scans.
- Warning now given when spectra are mathematically combined and are
not both in the same time/frequency domain.
- sum_mrs function added to simplify combining spectra within a
pipe.
- scale_mrs function added to simplify scaling a spectrum within a
pipe.
- add_noise function added to simplify generating simulated data with
a pipe.
- hsvd_filt function now accepts a frequency range in ppm units and
gives the option to return the model rather than the filtered data.
- Bug fix for hsvd_filt function where the max_damp argument was
ignored.
- SVS reference scans, found in some TWIX files, are now removed by
default.
- Bug fix for reading list/data when only one coil element is
used.
spant 1.12.0
- Added 2HG and citrate simulation parameters.
e.g. get_mol_paras(“2hg”).
- Better print output for molecular definitions.
- Added metabolite and basis simulation vignettes.
- Bug fix for setting the ppm reference when reading LCModel RAW
files.
- Bug fix for ABfit CRLB calculation of combined signals, eg tNAA,
tCr.
spant 1.11.0
- Options added to allow extra information to attached to mrs_data and
fit_result objects as a data frame.
- New functions (combine_fit_XXX) for working with multiple fit
results contained within a list structure.
- Basis set and noise region are now checked for validity in
ABfit.
- Added spant_abfit_benchmark function.
- Tentative functions for performing “standard” 1H brain analyses:
svs_1h_brain_analysis and svs_1h_brain_batch_analysis.
- Improved support for LCModel analyses.
spant 1.10.0
- Fix for NIfTI MRS reader/writer.
- ortho3 now shows correct labels for orientations other than
RAS.
- ortho3_int function renamed to ortho3_inter.
- Argument order change to plot_voi_overlay and plot_voi_overlay_seg
to be more consistent with ortho3.
- Regression fix for partial volume segmentation plotting.
- Echo time parameter is now stored in the meta structure.
- ABfit now performs a 1D phase parameter search before the prefit
stage to improve reliability. May be disabled with the
prefit_phase_search fit option.
spant 1.9.0
- NIfTI MRS reader and writer now uses the header extension for
metadata. Thanks to Jon Clayden for adding extension read/write support
to the RNifti package.
- Default plots now have gridlines in the y-direction and the plot
line is now thicker and coloured blue.
- Opacity option added to the plotting functions (alpha).
- Bug fix for comb_coils with SVS data.
- Bug fixes for Siemens geometry information.
- Changed the ordering of arguments to write_mrs and write_mrs_nifti
to improve consistency with other functions.
- Internal function (ortho3) now used to plot voxel locations on
MRI.
- Internal dicom reader function added.
- Tentative support for Siemens and Philips DICOM MRS format
added.
- Internal changes to the way orientation information is handled.
spant 1.8.0
- Added gridplot function.
- New functions added for down sampling.
- Added signal space projection method for MRSI.
- Geometry information is now read from Siemens twix files.
- GitHub actions are now used for continuous integration instead of
Travis and AppVeyor.
- Added precomp function to avoid repeated computation.
- mrs_data2mat function now collapses all dimensions to dynamics by
default.
- mrs_data objects now store the nucleus.
- Added a reader for old Varian format (fid/procpar) data.
spant 1.7.0
- Added write_mrs function which guesses the output format from the
file extension or can be specified as an argument. write_mrs_XXX
functions have been depreciated.
- read_mrs function now tries to guess the format from the file
extension.
- Added json sidecar to NIFTI MRS export function.
- Added the option to read MRS data from a NIFTI file and json sidecar
using the read_mrs function.
- Changed default crop_spec region to between 4.0 and 0.2 ppm.
spant 1.6.0
- Bug fix for GE P file reader.
- Added downsample_mrs function.
- Tentative function (write_mrs_nifti) to write MRS data as a NIFTI
format file
- for evaluation purposes only.
spant 1.5.0
- Added an option to ABfit to allow the metabolite amplitudes to be
negative (ahat_calc_method).
- Removed lsei package dependency.
spant 1.4.0
- Added the option to plot a y = 0 baseline trace for
stackplot.mrs_data.
- Added convenience functions to read and write mrs_data to rds
format.
spant 1.3.0
- Added get_fit_table function to combine all fit tables in a
fit_result object into a single dataframe.
- ppm function can now be applied to fit result objects.
- Bug fix for plot_slice_fit_inter and added the option to specify a
denominator.
- Added the option to specify a denominator to plot_slice_fit.
spant 1.2.1
- Added the option to display a progress bar in fit_mrs function for
better conformance to “Writing R Extensions” in non-interactive
use.
- Changed test tolerance to accommodate differences with OSX.
spant 1.2.0
- Performance improvement for HSVD water filter.
- ABfit unit tests are now run on simulated data to improve
consistency between different platforms.
- Improvements to fit amplitude scaling code.
- Improved checking for mrs_data processing functions.
- Added preprocessing steps vignette.
spant 1.1.0
- Improved ppm labels for ABfit plot results.
- Bug fix for plot_slice_fit when using fits from masked data.
- Updated unit tests.
- Added vignette on manually adjusting ABfit baseline smoothness.
- Updated the introduction vignette.
- Bug fixes for image and stackplot functions for masked MRS
data.
- Bug fix for using RATS with masked MRS data.
- Changes to prepare for for R 4.0.0.
spant 1.0.0
- ABfit analysis method has been added, and is now default for the
mrs_fit function.
- Added reader for LCModel RAW format data.
- Added read_mri_dyn_dir function for reading dynamic MRS exported
from Siemens scanners.
- Bug fixes for 2D MRSI voxel segmentation calculation.
- Bug fixes for Siemens IMA format reader for SVS data.
- Optional colourbar added to ortho3 function.
spant 0.19.0
- Added Asc, BHB, Cho, PEth and Ser simulation parameters.
- Added ker option to get_mrsi_voi function.
- Added append_basis function to combine two basis sets objects.
- The align function now accepts more than one reference
frequency.
spant 0.17.0
- Added a function to grid shift 2D MRSI data in the x/y
direction.
- Better plotting/fitting support for masking data by setting data
points to NA.
- Bug fix for interactive voxel selection position indicator.
- Added mask_xy to mask voxels in a centred rectangular region.
- Minor changes to improve parallel processing support.
spant 0.16.0
- SNR is now defined as the max data point divided by the standard
deviation of the noise (n.b. factor of two has been removed in-line with
upcoming terminology paper).
- Default rats method improved to work with multidimensional
datasets.
- Added norm_mrs function to normalise the intensity of spectral
data.
- Added bc_constant function to correct spectral baselines by a
constant offset.
- Added re_weighting function to apply a resolution enhancement
weighting to the FID.
- Performance improvement for apodise_xy function.
- sd function now works for mrs_data.
- Added 2D MRSI support for Siemens IMA format.
spant 0.15.0
- Bug fix for using auto_phase function with a single spectrum.
- Bug fix for comb_coils not returning unaveraged data when
requested.
- Added options to combine metabolite signals from the stackplot of a
fit object and adjust the plot margins.
- Added comb_fits function.
- Added collapse_to_dyns function for mrs_fit objects.
- RDA reader now extracts geometry information.
spant 0.14.0
- Added options to omit basis signals, change label names and combine
lipid and MM signals from the stackplot of a fit object.
- Added auto_phase function for zeroth order phase-correction of
simple spectra.
- Added get_subset function to aid MRSI slicing.
- Added decimate_mrs function.
- Added fit_amps function to quickly extract amplitude estimates from
a fit object.
- Bug fix for int_spec function.
- sim_basis function arguments updated to accept acq_par objects.
spant 0.13.0
- Various bug fixes for Siemens TWIX reader.
- rats and tdsr functions now use the mean spectrum as the default
reference.
- Added the option to remove the x axis in an mrs_data plot.
- Added ylim and y_scale options to fit plotting.
- Added %$% operator from magrittr package.
- Added an interpolation option to calc_spec_snr.
- Added hline and vline options to image.mrs_data.
spant 0.12.0
- Fit results stackplot now has the option to display labels.
- Added the option to reverse eddy current correction.
- Improved GE p-file reader.
- diff function can now be applied to mrs_data objects.
- Complex functions: Re, Im, Mod, Arg and Conj can now be applied to
mrs_data objects.
- Default simulations for Glc and NAAG have been improved.
spant 0.11.0
- Added mar argument to plot command.
- td2fd and fd2td now give warnings when used with data already in the
target domain.
- Improved documentation formatting consistency and fixed some
spelling errors.
- Added rats method.
spant 0.10.0
- The names of in-built pulse sequence functions now all start with
seq_* to make them easier to find.
- Added new functions to simulate the following MRS sequences: CPMG,
MEGA-PRESS, STEAM, sLASER. sLASER sequence kindly contributed by
Pierre-Gilles Henry.
- Bug fix for get_mol_names function.
- stackplot function now accepts labels argument and time-domain
plotting.
- def_acq_paras function now accepts arguments to override the
defaults.
- Added a source field to mol.paras object to cite the origin of the
values.
- Option to restore plotting par defaults.
- The magrittr pipe operator is now exported.
spant 0.9.0
- Updated plotting modes to be one of : “re”, “im”, “mod” or
“arg”.
- Updated int_spec function to use “re”, “im”, or “mod”.
- Added a function to replicate data across a particular
dimension.
- Added a convenience function to simulate normal looking 1H brain MRS
data.
- phase and shift functions now accept vector inputs.
spant 0.7.0
- Added new function for frequency drift correction.
- Added support for Siemens ima and TWIX SVS data.
- Added support for GE p-file SVS data.
- Added apply_axes fn.
- Support for reading SPM style segmentation results
(spm_pve2categorical).
spant 0.6.0
- Interactive plotting function added for fit results -
plot_fit_slice_inter.
- Bug fix for appending dynamic results.
- Bug fix for reading list data files without reference data.
- Bug fix for append_dyns function.
- basis2mrs_data function has been extended to allow the summation of
basis elements and setting of individual amplitudes.
- Added a shift function for manual frequency shift adjustment.
- Added initial unit tests and automated coveralls checking.
spant 0.5.0
- A default brain PRESS basis is now simulated by the fit_mrs function
when the basis argument isn’t specified.
- Added calc_peak_info function for simple singlet analyses.
- crop_spec function now maintains the original frequency scale.
- The basis set used for analyses has now been added to the fit result
object.
- Bug fix for simulating basis sets with one element.
- lb function can now be used with basis-set objects.
- Bug fix for spar_sdat reader for non-localised MRS.
- AppVeyor now being used to test Windows compatibility - John
Muschelli.
spant 0.4.0
- Bug fix for SPAR/SDAT SVS voxel dimensions.
- MRSI support added for Philips SPAR/SDAT data.
- Fit plots now default to the full spectral range unless xlim is
specified.
- Fit plots allow the x, y, z, coil, dynamic indices to be
specified.
- Added the option to subtract the baseline from fit plots.
spant 0.3.0
- Added stackplot method for fit objects.
- Added functions for registering and visualising SVS volumes on
images and performing partial volume correction.
- Philips “list data” also now reads noise scans.
- calc_coil_noise_cor, calc_coil_noise_sd functions added to aid coil
combination.
- Documentation updates for plotting methods.
- Added some simulation methods to userland.
spant 0.2.0
- Added Siemens RDA format reader.
- Added Philips “list data” format reader.
- Added Bruker paravision format reader.
- Added PROPACK option for HSVD based filtering.
- Added a coil combination function.
- Bug fix for incorrect ppm scale on fit plots when fs != 2000Hz.
- Bug fix for VARPRO analytical jacobian calculation.
spant 0.1.0
These binaries (installable software) and packages are in development.
They may not be fully stable and should be used with caution. We make no claims about them.