The hardware and bandwidth for this mirror is donated by METANET, the Webhosting and Full Service-Cloud Provider.
If you wish to report a bug, or if you are interested in having us mirror your free-software or open-source project, please feel free to contact us at mirror[@]metanet.ch.

spiro

Project Status: Active – The project has reached a stable, usable state and is being actively developed. CRAN status DOI R-CMD-check codecov Status at rOpenSci Software Peer Review

Overview

This R package offers a fast, standardized and reproducible workflow for data from cardiopulmonary exercise testing. It offers tools for data import, processing, summary and visualization.

Background

Measuring gas exchange during physical exercise is a common procedure in sports science and medicine. It allows to assess the functional limit of the cardiovascular system, evaluate the success of training interventions, and diagnose cardio-respiratory diseases. The measuring devices of cardiopulmonary exercise testing — so-called metabolic carts — output their data in different formats. Moreover, measured breath-by-breath data is noisy and requires post-processing. This package standardizes the import and processing of raw data from different metabolic carts.

Installation

Install spiro from CRAN:

install.packages("spiro")

Install the current development version of spiro from GitHub:

if (!require(remotes)) install.packages("remotes")
remotes::install_github("ropensci/spiro")

Usage

Main functions:

Further functionality:

Metabolic Carts

The following metabolic carts are currently supported by spiro:

Support for further metabolic carts is planned for future releases.

Example

library(spiro)

# get data path for example
file <- spiro_example("zan_gxt")

# import and process the raw data
gxt_data <- spiro(file)

# summary of parameters by load step
spiro_summary(gxt_data)
#> for pre-measures, interval was set to length of measures (60 seconds)
#>    step_number duration load     VO2    VCO2     VE HR PetO2 PetCO2 VO2_rel
#> 1            0       60  0.0  500.19  411.74  13.03 NA    NA     NA    7.58
#> 2            1      300  2.0 1860.92 1585.75  39.87 NA    NA     NA   28.20
#> 3            2      300  2.4 2097.82 1805.27  44.63 NA    NA     NA   31.79
#> 4            3      300  2.8 2413.01 2122.17  52.63 NA    NA     NA   36.56
#> 5            4      300  3.2 2710.68 2319.93  57.19 NA    NA     NA   41.07
#> 6            5      300  3.6 3048.75 2684.87  67.45 NA    NA     NA   46.19
#> 7            6      300  4.0 3404.02 3026.70  75.91 NA    NA     NA   51.58
#> 8            7      300  4.4 3724.37 3383.64  88.36 NA    NA     NA   56.43
#> 9            8      300  4.8 4223.82 3993.55 106.44 NA    NA     NA   64.00
#> 10           9      300  5.2 4573.91 4488.36 127.54 NA    NA     NA   69.30
#>        RE  RER  CHO   FO
#> 1      NA 0.82 0.27 0.15
#> 2  234.97 0.85 1.27 0.46
#> 3  220.73 0.86 1.51 0.49
#> 4  217.62 0.88 1.95 0.48
#> 5  213.91 0.86 1.89 0.65
#> 6  213.86 0.88 2.47 0.60
#> 7  214.90 0.89 2.90 0.62
#> 8  213.75 0.91 3.50 0.56
#> 9  222.21 0.95 4.68 0.37
#> 10 222.12 0.98 5.82 0.12

# maximum values
spiro_max(gxt_data)
#>       VO2    VCO2     VE VO2_rel  RER HR
#> 1 4732.28 4640.75 129.62    71.7 0.99 NA

# Wassermann 9-Panel Plot
spiro_plot(gxt_data)

Citation

citation("spiro")
#> 
#> To cite spiro in publications use:
#> 
#>   Simon Nolte (2023). spiro: An R package for analyzing data from
#>   cardiopulmonary exercise testing. Journal of Open Source Software,
#>   8(81), 5089, https://doi.org/10.21105/joss.05089
#> 
#> A BibTeX entry for LaTeX users is
#> 
#>   @Article{,
#>     title = {spiro: An R package for analyzing data from cardiopulmonary exercise testing},
#>     author = {Simon Nolte},
#>     year = {2023},
#>     volume = {8},
#>     number = {81},
#>     pages = {5089},
#>     journal = {Journal of Open Source Software},
#>     url = {https://joss.theoj.org/papers/10.21105/joss.05089},
#>     doi = {10.21105/joss.05089},
#>   }

The whippr package offers a different approach to working with data from cardiopulmonary exercise testing. It additionally offers functions for analyzing VO2 kinetics.

Acknowledgment

The following persons contributed to this package by providing raw data files, reviewing code and/or suggesting features: Daniel Appelhans, James Hunter, Virgile Lecoultre, Sebastian Mühlenhoff, Manuel Ramon, Anton Schiffer, Yannick Schwarz, Adrian Swoboda, Andreas Wagner.

Contributing

If you consider contributing to this package, read the CONTRIBUTING.md. Please note that this package is released with a Contributor Code of Conduct. By contributing to this project, you agree to abide by its terms.

These binaries (installable software) and packages are in development.
They may not be fully stable and should be used with caution. We make no claims about them.