The hardware and bandwidth for this mirror is donated by METANET, the Webhosting and Full Service-Cloud Provider.
If you wish to report a bug, or if you are interested in having us mirror your free-software or open-source project, please feel free to contact us at mirror[@]metanet.ch.

(advanced) Local decorrelation for time series

The decorrelation of the measures in repeated-measure designs is meant to have error bars that are integrating the added power of using repeated-measures over independent groups. In design with a few measurements, the correlation between the pairs of measurements is indicative of the gain in statistical power. However, in time series, correlation is likely to vanish as measurements get further spaced in time (the lag effect).

For example, consider a longitudinal study of adolescents over 10 years. The measurements that are 6-month apart may show some correlations, but the two most separated measurements (say the first at 8 years old and the second at 18 years old) are much less likely to preserve their correlations.

This vignette propose a solution. It is detailed in Cousineau, Proulx, Potvin-Pilon, & Fiset (2024).

The structure of correlations

When repeated measures are obtained, one may compute the correlation matrix. The correlation matrix is always composed of 1s along the main diagonal, as the correlation of a variable with itself is always 1. What is more interesting is what happen off the main diagonal.

In some situations, the correlations are fairly constant (stationary). When the variance are further homogeneous, this correlation structure is known as compound symmetry. Compound symmetry is the simplest situation and also the easiest to analyze (with e.g., ANOVAs, alghough ANOVA really requires sphericity, a slightly different correlation structure).

In other situations, we might see that correlations near the main diagnonal are strong, but as we distance from the diagonal (either in the upper-right or lower-left directions), the correlations slowly vanishes, possibly reaching near-null values. This structure is known as an autoregressive covariance structure of the first order or AR(1). In time series, that would indicate that the correlation of a measurement with the measurement just before or just after is high, but that the correlation between a measurement and a distant measurement is weak.

Implications for precision

Vanishing correlations means that comparing distant points in time will be performed with weaker statistical precision and comparisons of close-by measures will benefit from much correlation (correlation is your friend when it comes to statistical inference).

In plotting curves, our objective may be to see how the points evolves, which imply that we are making multiple comparisons of close-by points. If so, our visual tools should be based on the correlation (presumably high) between these nearby points. If our objective is instead to compare far-distance points, the visual tools should incorporate the correlations of these distant points (presumably weak).

How is correlation assessed then?

There are a few techniques to estimate the correlation in a correlation matrix. When it is assumed compound symmetric, the average of the pairwise correlations is satisfactory. When it is AR(1) however, the average won’t do as the correlation is varying based on the lag.

We argue that a fit technique is to average the correlations using weights that are reducing with distance (excluding the main diagonal whose weight is set to 0). Any kernel (for example a gaussian kernel) can be used to that end, as long as the width is kept smaller than the number of variables. We implemtented this technique in superb.

Illustration with fMRI data

Waskom, Frank, & Wagner (2017) examined the finite impulse response obtained from an fMRI for two sites (frontal and parietal) and two event conditions (a cue-only condition and a cue+stimulus condition). The responses are obtained over 19 time points (labeled 0 to 18) in these four conditions, resulting in 76 measurements. There are 14 participants.

We first fetch the data from the main author’s GitHub repository:

fmri <- read.csv(url("https://raw.githubusercontent.com/mwaskom/seaborn-data/de49440879bea4d563ccefe671fd7584cba08983/fmri.csv"))
# sort the data...
fmri <- fmri[order(fmri$subject, fmri$event, fmri$region, fmri$timepoint),]

We are ready to make plots!

A plot without decorrelation

The first plot is done without adjustments. By default, it shows the standalone 95% confidence interval. The formula uses the long data format but specifies that the observations are nested with subject numbers:

superb( 
    signal ~ timepoint + region + event | subject,
    fmri,
    plotStyle = "lineBand",
    pointParams = list(size=1,color="black"),
    lineParams = list(color="purple")
) + scale_x_discrete(name="Time", labels = 0:18) + 
scale_discrete_manual(aesthetic =c("fill","colour"), 
                      labels = c("frontal","parietal"), 
                      values = c("red","green")) +
theme_bw() + ylim(-0.15, +0.35) 
Figure 1. Plot of the fMRI data with standalone confidence intervals.
Figure 1. Plot of the fMRI data with standalone confidence intervals.

The scale_x_discrete is done to rename the ticks from 0 to 18 (they would start at 1 otherwise). The scale_discrete_manual changes the color of the band (I hope you are color-blind, colors is not my thing). The plotStyle = "lineBand" displays the confidence intervals as a band rather than as error bars.

Plots with decorrelation

The decorrelation technique was first proposed by Loftus & Masson (1994). Alternatives approaches were developped in Cousineau (2005) with Morey (2008; also see Cousineau, 2019). They are known in superbPlot() as "LM" and "CM" respectively.

If you add this adjustment with this command, you get the following plot:

superb( 
    signal ~ timepoint + region + event | subject,
    fmri,
    adjustments = list(decorrelation = "CM"), ## only new line
    plotStyle = "lineBand",
    pointParams = list(size=1,color="black"),
    lineParams = list(color="purple")
) + scale_x_discrete(name="Time", labels = 0:19) + 
scale_discrete_manual(aesthetic =c("fill","colour"), 
                      labels = c("frontal","parietal"), 
                      values = c("red","green"))+
theme_bw() + ylim(-0.15, +0.35) + 
showSignificance(c(6,7)+1, 0.3, -0.02, "n.s.?", panel=list(event=2)) 
## superb::FYI: The HyunhFeldtEpsilon measure of sphericity per group are  0.052
## superb::FYI: All the groups' data are compound symmetric. Consider using CA or UA.
Figure 2. Plot of the fMRI data with Cousineau-Morey decorrelation.
Figure 2. Plot of the fMRI data with Cousineau-Morey decorrelation.

As you may see, this plot and the previous one are nearly identical! This is because the average correlation involving close-by and far-distant points is very weak (close to zero; replace CM with CA and a message will return the average correlation in addition to a plot).

Because fMRI points are separated by time, close-by points ought to show some correlation. This is where local decorrelation may be useful.

We repeat the above command, but this time ask for a local average of the correlation. We need to specify the radius of the kernel, which we do by adding an integer after the letters “LD”. Here, we show the results with a narrow kernel, weighting far more adjacent points than points 3 time points appart, obtained with "LD2":

superb( 
    signal ~ timepoint + region + event | subject,
    fmri,
    adjustments = list(decorrelation = "LD2"),  ## CM replaced with LD2
    plotStyle = "lineBand",
    pointParams = list(size=1,color="black"),
    lineParams = list(color="purple")
) + scale_x_discrete(name="Time", labels = 0:19) + 
scale_discrete_manual(aesthetic =c("fill","colour"), 
                      labels = c("frontal","parietal"), 
                      values = c("red","green"))+
theme_bw() + ylim(-0.15, +0.35) + 
showSignificance(c(6,7)+1, 0.3, -0.02, "**!", panel=list(event=2)) 
## superb::FYI: The average correlation per group is  0.5158
Figure 3. Plot of the fMRI data with local decorrelation.
Figure 3. Plot of the fMRI data with local decorrelation.

As seen from the message, the correlations in nearby time points is about .50. It explains why the precision of the measures shrank so much (seen with confidence intervals that are much narrower). You can pick any two nearby points and run a paired t-test, the chances are high that you get a significant result.

As an example, consider the green curve, in condition cue+stimuli (i.e., bottom panel), for time points 6 and 7. The confidence band suggest that these two points differ when you examine the locally-decorrelated confidence intervals, but not when you examine the previous two plots. Which is true? Let’s run a t-test on paired sample.

d1 <- dplyr::filter(fmri, event=="stim" & region=="parietal" & timepoint==6)
d2 <- dplyr::filter(fmri, event=="stim" & region=="parietal" & timepoint==7)

t.test(d1$signal, d2$signal, paired=TRUE)
## 
##  Paired t-test
## 
## data:  d1$signal and d2$signal
## t = 3.8818, df = 13, p-value = 0.00189
## alternative hypothesis: true mean difference is not equal to 0
## 95 percent confidence interval:
##  0.02729823 0.09581713
## sample estimates:
## mean difference 
##      0.06155768

The radius parameter

You can vary the radius from 1 and above. The larger the radius, the smallest will be the benefit of correlation in the assessment of precision. In the extreme, if you use a very large radius (e.g., “LD10000”), you will get the exact same average correlation as with “CA” as now all the correlations are weighted almost identically.

Note that in the above computations, I reduced the number of messages displayed by superb() using options("superb.feedback" = "warnings" ).

Difference adjustments

In all three figures, we did not use the difference adjustment. Recall that this adjustment is needed when the objective of the error bars (or error bands) is to perform comparisons between pairs of conditions.

In the present example, the reader is very likely to perform comparisons between curves so that the difference adjustment is very much needed. Simply add purpose = "difference" in the adjustments list of the three examples above. You will see that of the three plots above, only the locally-decorrelated one suggests significant differences between the bottom curves on some time points, which is indeed what format tests indicate.

In summary

Local decorrelation is a tool adapted to time series where nearby measurements are expected to show greater correlations than measurements separated by large amount of time. This is applicable among other to time series, longitudinal studies, fMRI studies (as the example above) and EEG studies (as the application described in Cousineau et al. (2024)).

References

Cousineau, D. (2005). Confidence intervals in within-subject designs: A simpler solution to Loftus and Masson’s method. Tutorials in Quantitative Methods for Psychology, 1, 42–45. https://doi.org/10.20982/tqmp.01.1.p042
Cousineau, D. (2019). Correlation-adjusted standard errors and confidence intervals for within-subject designs: A simple multiplicative approach. The Quantitative Methods for Psychology, 15, 226–241. https://doi.org/10.20982/tqmp.15.3.p226
Cousineau, D., Proulx, A., Potvin-Pilon, A., & Fiset, D. (2024). Local decorrelation for error bars in time series. The Quantitative Methods for Psychology, 20(2), 173–185. https://doi.org/10.20982/tqmp.20.2.p173
Loftus, G. R., & Masson, M. E. J. (1994). Using confidence intervals in within-subject designs. Psychonomic Bulletin & Review, 1, 476–490. https://doi.org/10.3758/BF03210951
Morey, R. D. (2008). Confidence intervals from normalized data: A correction to Cousineau (2005). Tutorials in Quantitative Methods for Psychology, 4, 61–64. https://doi.org/10.20982/tqmp.04.2.p061
Waskom, M. L., Frank, M. C., & Wagner, A. D. (2017). Adaptive engagement of cognitive control in context-dependent decision making. Cerebral Cortex, 27, 1270–1284. https://doi.org/10.1093/cercor/bhv333

These binaries (installable software) and packages are in development.
They may not be fully stable and should be used with caution. We make no claims about them.