The hardware and bandwidth for this mirror is donated by METANET, the Webhosting and Full Service-Cloud Provider.
If you wish to report a bug, or if you are interested in having us mirror your free-software or open-source project, please feel free to contact us at mirror[@]metanet.ch.

Bayesian Univariate Gaussian Mixtures with the Telescoping Sampler

Gertraud Malsiner-Walli, Sylvia Frühwirth-Schnatter, Bettina Grün

Introduction

In this vignette we fit a Bayesian univariate Gaussian mixture with a prior on the number of components \(K\) to the Galaxy data set. We use the prior specification and the telescoping sampler for performing MCMC sampling as proposed in Frühwirth-Schnatter, Malsiner-Walli, and Grün (2021). The Galaxy data set has already been used in Richardson and Green (1997) for fitting a Bayesian mixture with an unknown number of components, exploiting that for certain prior specifications the posterior for the number of components as well as data clusters in the data set is rather dispersed. More results on the analysis of the Galaxy data set using Bayesian mixtures of univariate Gaussian distributions are provided in Grün, Malsiner-Walli, and Frühwirth-Schnatter (2022).

First, we load the package.

library("telescope")

The Galaxy data set

The Galaxy data set is quite small. We directly insert the values into R.

y <- c( 9.172,  9.350,  9.483,  9.558,  9.775, 10.227,
       10.406, 16.084, 16.170, 18.419, 18.552, 18.600,
       18.927, 19.052, 19.070, 19.330, 19.343, 19.349,
       19.440, 19.473, 19.529, 19.541, 19.547, 19.663,
       19.846, 19.856, 19.863, 19.914, 19.918, 19.973,
       19.989, 20.166, 20.175, 20.179, 20.196, 20.215,
       20.221, 20.415, 20.629, 20.795, 20.821, 20.846,
       20.875, 20.986, 21.137, 21.492, 21.701, 21.814,
       21.921, 21.960, 22.185, 22.209, 22.242, 22.249,
       22.314, 22.374, 22.495, 22.746, 22.747, 22.888,
       22.914, 23.206, 23.241, 23.263, 23.484, 23.538,
       23.542, 23.666, 23.706, 23.711, 24.129, 24.285,
       24.289, 24.368, 24.717, 24.990, 25.633, 26.960,
       26.995, 32.065, 32.789, 34.279)
N <- length(y)

The data is visualized in a histogram, indicating multi-modality in the distribution but also some ambiguity about the number of modes.

hist(y, breaks = 50, main = "", col = "lightgray")   

Model specification

For univariate observations \(y_1,\ldots,y_N\) the following model with hierarchical prior structure is assumed:

\[\begin{aligned} y_i \sim \sum_{k=1}^K \eta_k f_N(\mu_k,\sigma_k^2)&\\ K \sim p(K)&\\ \boldsymbol{\eta} \sim Dir(e_0)&, \qquad \text{with } e_0 \text{ fixed, } e_0\sim p(e_0) \text {, or } e_0=\frac{\alpha}{K}, \text{ with } \alpha \text{ fixed or } \alpha \sim p(\alpha),\\ \mu_k\sim N(b_0,B_0)\\ \sigma_k^2 \sim \mathcal{G}^{-1}(c_0,C_0)& \qquad \text{with }E(\sigma_k^2) = C_0/(c_0-1),\\ C_0 \sim \mathcal{G}(g_0,G_0)& \qquad \text{with }E(C_0) = g_0/G_0. \end{aligned}\]

Specification of the MCMC simulation and prior parameters

For MCMC sampling we need to specify Mmax, the maximum number of iterations, thin, the thinning imposed to reduce auto-correlation in the chain by only recording every thined observation, and burnin, the number of burn-in iterations not recorded.

Mmax <- 10000
thin <- 1
burnin <- 100

The specifications of Mmax and thin imply M, the number of recorded observations.

M <- Mmax/thin

For MCMC sampling, we need to specify Kmax, the maximum number of components possible during sampling, and Kinit, the initial number of filled components.

Kmax <- 50  
Kinit <- 10

We use a static specification for the weights with a fixed prior on \(e_0\) where the value is set to 1.

G <- "MixStatic" 
priorOnE0 <- priorOnE0_spec("e0const", 1)

We need to select the prior on K. We use the uniform prior on [1, 30] as also previously used in Richardson and Green (1997).

priorOnK <- priorOnK_spec("Unif", 30)

We specify the component-specific priors on \(\mu_k\) and \(\sigma_k^2\) following Richardson and Green (1997).

r <- 1    # dimension
R <- diff(range(y))
c0 <- 2 + (r-1)/2
C0 <- diag(c(0.02*(R^2)), nrow = r)
g0 <- 0.2 + (r-1) / 2
G0 <- diag(10/(R^2), nrow = r)
B0 <- diag((R^2), nrow = r)
b0 <- as.matrix((max(y) + min(y))/2, ncol = 1)  

To start the MCMC sampling an initial partition of the data as well as initial parameter values need to be provided. We use kmeans() to determine the initial partition \(S_0\) as well as the initial component-specific means \(\mu_0\).

set.seed(1234)
cl_y <- kmeans(y, centers = Kinit, nstart = 30)
S_0 <- cl_y$cluster
mu_0 <- t(cl_y$centers)

For the further parameters we use initial values corresponding to equal component sizes and half of the value of C0 for the variances.

Initial values for parameters:

eta_0 <- rep(1/Kinit, Kinit)
sigma2_0 <- array(0, dim = c(1, 1, Kinit))
sigma2_0[1, 1, ] <- 0.5 * C0

MCMC sampling

Using this prior specification as well as initialization and MCMC settings, we draw samples from the posterior using the telescoping sampler.

The first argument of the sampling function is the data followed by the initial partition and the initial parameter values for component-specific means, variances and sizes. The next set of arguments correspond to the hyperparameters of the prior setup (c0, g0, G0, C0, b0, B0). Then, the setting for the MCMC sampling are specified using M, burnin, thin and Kmax. Finally the prior specification for the weights and the prior on the number of components are given (G, priorOnK, priorOnE0).

estGibbs <- sampleUniNormMixture(
    y, S_0, mu_0, sigma2_0, eta_0,
    c0, g0, G0, C0, b0, B0, 
    M, burnin, thin, Kmax,
    G, priorOnK, priorOnE0)

The sampling function returns a named list where the sampled parameters and latent variables are contained. The list includes the component means Mu, the weights Eta, the assignments S, the number of observations Nk assigned to components, the number of components K, the number of filled components Kplus, parameter values corresponding to the mode of the nonnormalized posterior nonnormpost_mode_list, the acceptance rate in the Metropolis-Hastings step when sampling \(\alpha\) or \(e_0\), \(\alpha\) and \(e_0\). These values can be extracted for post-processing.

Mu <- estGibbs$Mu
Eta <- estGibbs$Eta
S <- estGibbs$S
Nk <- estGibbs$Nk
K <- estGibbs$K
Kplus <- estGibbs$Kplus  
nonnormpost_mode_list <- estGibbs$nonnormpost_mode_list
acc <- estGibbs$acc
e0 <- estGibbs$e0
alpha <- estGibbs$alpha  

Convergence diagnostics of the run

There is no need to inspect the hyperparameters for the weight distribution as a fixed value has been specified for e0. To assess convergence, we inspect the trace plots for the number of components \(K\) and the number of filled components \(K_+\).

plot(seq_along(K), K, type = "l", ylim = c(0, 30),  
     xlab = "iteration", main = "",
     ylab = expression("K" ~ "/" ~ K["+"]),
     lwd = 0.5, col = "grey")
lines(seq_along(Kplus), Kplus, col = "red3", lwd = 2, lty = 1)
legend("topright", legend = c("K", "K+"),
       col = c("grey", "red3"), lwd = 2)

Identification of the mixture model

Step 1: Estimating \(K_+\) and \(K\)

We determine the posterior distribution of the number of filled components \(K_+\) approximated using the telescoping sampler. We visualize the distribution using a barplot.

Kplus <- rowSums(Nk != 0, na.rm = TRUE)  
p_Kplus <- tabulate(Kplus, nbins = max(Kplus))/M  
barplot(p_Kplus/sum(p_Kplus), names = 1:length(p_Kplus), 
        col = "red3", xlab = expression(K["+"]),
        ylab = expression("p(" ~ K["+"] ~ "|" ~ bold(y) ~ ")"))

The distribution of \(K_+\) is also characterized using the 1st and 3rd quartile as well as the median.

quantile(Kplus, probs = c(0.25, 0.5, 0.75))
## 25% 50% 75% 
##   5   6   7

We obtain a point estimate for \(K_+\) by taking the mode and determine the number of MCMC draws where exactly \(K_+\) components were filled.

Kplus_hat <- which.max(p_Kplus)
Kplus_hat
## [1] 5
M0 <- sum(Kplus == Kplus_hat)
M0          
## [1] 2581

We also determine the posterior distribution of the number of components \(K\) directly drawn using the telescoping sampler.

p_K <- tabulate(K, nbins = max(K, na.rm = TRUE))/M
round(p_K[1:20], digits = 2)
##  [1] 0.00 0.00 0.05 0.15 0.21 0.20 0.16 0.11 0.06 0.03 0.02 0.01 0.00 0.00 0.00
## [16] 0.00 0.00 0.00 0.00 0.00
barplot(p_K/sum(p_K), names = 1:length(p_K), xlab = "K", 
        ylab = expression("p(" ~ K ~ "|" ~ bold(y) ~ ")"))

Again the posterior mode can be determined as well as the posterior mean and quantiles of the posterior.

which.max(tabulate(K, nbins = max(K)))
## [1] 5
mean(K)
## [1] 6.2524
quantile(K, probs = c(0.25, 0.5, 0.75))
## 25% 50% 75% 
##   5   6   7

For the prior specification used, clearly the posterior distributions for \(K_+\) and \(K\) indicate that the posterior weight is quite dispersed over a larger range of values.

Step 2: Extracting the draws with exactly \(\hat{K}_+\) non-empty components

First we select those draws where the number of filled components was exactly \(\hat{K}_+\):

index <- Kplus == Kplus_hat
Nk[is.na(Nk)] <- 0
Nk_Kplus <- (Nk[index, ] > 0)

In the following we extract the cluster means, data cluster sizes and cluster assignments for the draws where exactly \(\hat{K}_+\) components were filled.

Mu_inter <- Mu[index, , , drop = FALSE]
Mu_Kplus <- array(0, dim = c(M0, 1, Kplus_hat)) 
Mu_Kplus[, 1, ] <- Mu_inter[, 1, ][Nk_Kplus]

Eta_inter <- Eta[index, ]
Eta_Kplus <- matrix(Eta_inter[Nk_Kplus], ncol = Kplus_hat)
Eta_Kplus <- sweep(Eta_Kplus, 1, rowSums(Eta_Kplus), "/")

w <- which(index)
S_Kplus <- matrix(0, M0, length(y))
for (i in seq_along(w)) {
    m <- w[i]
    perm_S <- rep(0, Kmax)
    perm_S[Nk[m, ] != 0] <- 1:Kplus_hat
    S_Kplus[i, ] <- perm_S[S[m, ]]
}

Step 3: Clustering and relabeling of the MCMC draws in the point process representation

For model identification, we cluster the draws of the means where exactly \(\hat{K}_+\) components were filled in the point process representation using \(k\)-means clustering.

Func_init <- nonnormpost_mode_list[[Kplus_hat]]$mu  
identified_Kplus <- identifyMixture(
    Mu_Kplus, Mu_Kplus, Eta_Kplus, S_Kplus, Func_init)

A named list is returned which contains the proportion of draws where the clustering did not result in a permutation and hence no relabeling could be performed and the draws had to be omitted.

identified_Kplus$non_perm_rate
## [1] 0.600155

Step 4: Estimating data cluster specific parameters and determing the final partition

The relabeled draws are also returned which can be used to determine posterior mean values for data cluster specific parameters.

colMeans(identified_Kplus$Mu)
## [1]  9.715797 22.796748 19.809047 16.312037 33.018958
colMeans(identified_Kplus$Eta)
## [1] 0.09447080 0.48758722 0.33565883 0.03624708 0.04603607

A final partition is obtained based on the relabeled cluster assignments by assigning each observation to the cluster it has been assigned most often during sampling.

z_sp <- apply(identified_Kplus$S, 2,
              function(x) which.max(tabulate(x, Kplus_hat)))
table(z_sp)
## z_sp
##  1  2  3  4  5 
##  7 39 31  2  3

Step 5: Visualizing the estimated classification

hist(y, breaks = 50)
points(cbind(y, rep(0, N)), col = z_sp, lwd = 2)

References

Frühwirth-Schnatter, Sylvia, Gertraud Malsiner-Walli, and Bettina Grün. 2021. “Generalized Mixtures of Finite Mixtures and Telescoping Sampling.” Bayesian Analysis 16 (4): 1279–1307. https://doi.org/10.1214/21-BA1294.
Grün, Bettina, Gertraud Malsiner-Walli, and Sylvia Frühwirth-Schnatter. 2022. “How Many Data Clusters Are in the Galaxy Data Set? Bayesian Cluster Analysis in Action.” Advances in Data Analysis and Classification 16 (2): 325–49. https://doi.org/10.1007/s11634-021-00461-8.
Richardson, Sylvia, and Peter J. Green. 1997. “On Bayesian Analysis of Mixtures with an Unknown Number of Components.” Journal of the Royal Statistical Society, Series B 59 (4): 731–92. https://doi.org/10.1111/1467-9868.00095.

These binaries (installable software) and packages are in development.
They may not be fully stable and should be used with caution. We make no claims about them.