Package {zentraR}


Title: R Client for the ZENTRA Cloud V5 API
Version: 0.1.3
Description: Downloads environmental sensor data from the ZENTRA Cloud V5 API (https://api.zentracloud.io) into tidy data frames. Provides device discovery, reading retrieval with automatic pagination and rate-limit handling, tidy long output with a wide-format helper, and an incremental 'sync' engine with pluggable local storage (RDS files, CSV files, or return-only) so that new readings can be fetched on a schedule and appended to a growing local record.
License: MIT + file LICENSE
Encoding: UTF-8
Depends: R (≥ 4.1.0)
Imports: cli, httr2 (≥ 1.0.0), rlang (≥ 1.0.0), tibble, tidyr, vctrs
Suggests: jsonlite, knitr, rmarkdown, testthat (≥ 3.0.0), withr
Config/testthat/edition: 3
VignetteBuilder: knitr
URL: https://gitlab.com/meter-group-inc/pubpackages/zentraR
BugReports: https://gitlab.com/meter-group-inc/pubpackages/zentraR/-/work_items
Config/roxygen2/version: 8.0.0
NeedsCompilation: no
Packaged: 2026-07-30 18:31:17 UTC; travis
Author: Travis Bates [aut, cre], METER Group, Inc. [cph, fnd]
Maintainer: Travis Bates <travis@metergroup.com>
Repository: CRAN
Date/Publication: 2026-08-07 17:20:02 UTC

zentraR: R Client for the ZENTRA Cloud V5 API

Description

Downloads environmental sensor data from the ZENTRA Cloud V5 API (https://api.zentracloud.io) into tidy data frames. Provides device discovery, reading retrieval with automatic pagination and rate-limit handling, tidy long output with a wide-format helper, and an incremental 'sync' engine with pluggable local storage (RDS files, CSV files, or return-only) so that new readings can be fetched on a schedule and appended to a growing local record.

Author(s)

Maintainer: Travis Bates travis@metergroup.com

Authors:

Other contributors:

See Also

Useful links:


ZENTRA device and sensor error codes

Description

Returns the lookup table of error_code values that can appear on readings. A code of 0 means the reading is valid; any non-zero code flags a device or sensor problem.

Usage

zc_error_codes()

Value

A tibble with columns error_code and error_label.

Examples

zc_error_codes()

Download sensor readings for a device

Description

Fetches time-series readings for a single device and returns them in a tidy "long" data frame: one row per (port, measurement, timestamp). All pages are retrieved automatically, and the request is paced to respect the API rate limit.

Usage

zc_get_readings(
  device_id,
  start = NULL,
  end = NULL,
  start_timestamp = NULL,
  end_timestamp = NULL,
  direction = "ascending",
  units = "metric",
  max_pages = Inf,
  progress = NULL,
  key = NULL
)

Arguments

device_id

Device identifier (string), e.g. "z6-00930" or "A4100110". See zc_list_devices().

start, end

Start/end of the window. Accepts a Date, POSIXct, numeric epoch seconds, or an ISO 8601 string. Interpreted as UTC when no timezone is present.

start_timestamp, end_timestamp

Alternative window as Unix epoch seconds (UTC). Mutually exclusive with start/end.

direction

Sort order by time: "ascending" (default) or "descending".

units

"metric" (default) or "imperial".

max_pages

Maximum number of pages (calendar-month windows) to fetch. Defaults to Inf (all available). Useful to cap very large backfills.

progress

Show a live progress indicator while pages are fetched? NULL (default) shows one in interactive sessions; set TRUE/FALSE to force it, or set options(zentraR.progress = FALSE) to turn it off globally. During a rate-limit pause the request waits and the underlying HTTP client reports the wait.

key

Optional API key. Defaults to the key set with zc_set_key() or the ZENTRACLOUD_API_KEY environment variable.

Details

Specify the time window with start/end (any of a Date, POSIXct, numeric epoch seconds, or an ISO 8601 string) or with start_timestamp/ end_timestamp (epoch seconds) - but not both. All datetimes are normalised to UTC. If you omit the window, the API returns its default (most recent) window.

Value

A tibble with columns device_id, datetime (POSIXct, UTC), timestamp (numeric epoch seconds), port_num, sensor_name, measurement, value, unit, and error_code (0 = valid; see zc_error_codes()).

Examples

## Not run: 
zc_set_key("my-secret-key")

# Last 7 days:
zc_get_readings("z6-00930", start = Sys.Date() - 7)

# An explicit window:
zc_get_readings(
  "z6-00930",
  start = as.POSIXct("2026-05-01", tz = "UTC"),
  end   = as.POSIXct("2026-06-01", tz = "UTC")
)

## End(Not run)

Check whether an API key is available

Description

Check whether an API key is available

Usage

zc_has_key()

Value

TRUE if a key has been set with zc_set_key() or is present in the ZENTRACLOUD_API_KEY environment variable, otherwise FALSE.


Add human-readable error labels to readings

Description

Joins the zc_error_codes() table onto a readings data frame, adding an error_label column so quality flags are easy to read and filter.

Usage

zc_label_errors(readings)

Arguments

readings

A data frame from zc_get_readings() with an error_code column.

Value

readings with an added error_label character column. Unknown codes get an "Unknown error code (<n>)" label.

Examples

## Not run: 
r <- zc_get_readings("z6-00930", start = Sys.Date() - 2)
zc_label_errors(r)

## End(Not run)

List the devices your API key can access

Description

Returns one row per device the authenticated key is allowed to see. Use this to discover device ids before calling zc_get_readings() or zc_sync(). All pages are fetched automatically.

Usage

zc_list_devices(
  organization_id = NULL,
  expand = NULL,
  limit = 1000L,
  max_pages = Inf,
  key = NULL
)

Arguments

organization_id

Optional organization id (UUID string) to restrict the list to a single organization.

expand

Optional character vector of extra detail to attach to each device. Any of "max_min_timestamp" (first/last measurement times), "settings", "hardware", "connectivity", "subscription". Adds extra columns to the result.

limit

Devices requested per API page (1-1000, default 1000). Affects only the number of underlying requests, not the returned data.

max_pages

Maximum number of pages to fetch. Defaults to Inf (all).

key

Optional API key. Defaults to the key set with zc_set_key() or the ZENTRACLOUD_API_KEY environment variable.

Value

A tibble with one row per device. Always includes device_id, name, organization_id, organization_name, device_type, and model. Requesting expand adds further columns (for example first_measurement and last_measurement as POSIXct times when "max_min_timestamp" is requested).

Examples

## Not run: 
zc_set_key("my-secret-key")
zc_list_devices()
zc_list_devices(expand = "max_min_timestamp")

## End(Not run)

Reshape tidy readings into wide format

Description

Turns the tidy "long" output of zc_get_readings() (one row per measurement) into a wide table with one row per timestamp and one column per measurement. This is the familiar "spreadsheet" layout for a single device.

Usage

zc_pivot_wider(readings, values_from = "value", names_sep = "_")

Arguments

readings

A data frame from zc_get_readings() (tidy long format).

values_from

Name of the column to spread into the wide cells. Defaults to "value".

names_sep

Separator used when a measurement name is combined with a port number. Defaults to "_".

Details

Note that the wide layout drops the per-reading unit and error_code columns (a single measurement column cannot carry them). Keep the tidy long form if you need units or quality flags alongside each value. When a device reports the same measurement on more than one port, the port number is appended to the column name to keep them distinct.

Value

A tibble with device_id, datetime, timestamp, and one column per measurement.

Examples

## Not run: 
r <- zc_get_readings("z6-00930", start = Sys.Date() - 2)
zc_pivot_wider(r)

## End(Not run)

Set your ZENTRA Cloud API key

Description

Stores your ZENTRA Cloud v5 API key so that the other ⁠zc_*()⁠ functions can authenticate. By default the key is kept for the current R session only. Set install = TRUE to also save it to your user .Renviron file so it is available in every future session.

Usage

zc_set_key(key, install = FALSE, overwrite = FALSE)

Arguments

key

Your API key, as a string.

install

If TRUE, write the key to your user .Renviron as ZENTRACLOUD_API_KEY so it persists across sessions. Defaults to FALSE.

overwrite

If TRUE, replace an existing ZENTRACLOUD_API_KEY entry in .Renviron when install = TRUE. Defaults to FALSE.

Details

Get your key from ZENTRA Cloud: User Account -> Integrations -> Show Token (https://app.zentracloud.io/profile/integrations). Treat it like a password. Regenerating it in ZENTRA Cloud immediately invalidates the old key.

Value

Invisibly, the key.

Examples

## Not run: 
# Keep the key for this session only:
zc_set_key("my-secret-key")

# Persist it across sessions:
zc_set_key("my-secret-key", install = TRUE)

## End(Not run)

Read, write, and inspect a zentraR store

Description

Low-level accessors for a store created by zc_store_rds(), zc_store_csv(), or zc_store_memory(). Most users interact with stores only through zc_sync(), but these are exported for direct access to the stored data.

Usage

zc_store_read(store, device_id = NULL)

zc_store_write(store, readings)

zc_store_last_time(store, device_id)

Arguments

store

A store object.

device_id

Optional device id. For zc_store_read(), NULL reads all devices. For zc_store_last_time() a single device id is required.

readings

A tidy readings data frame (as returned by zc_get_readings()).

Value

zc_store_read() returns a tidy readings tibble. zc_store_write() invisibly returns the store. zc_store_last_time() returns the latest stored timestamp (numeric epoch seconds) for the device, or NA_real_ if the device has no stored data.

Examples

## Not run: 
store <- zc_store_csv("data")
zc_store_read(store)
zc_store_last_time(store, "z6-00930")

## End(Not run)

Store readings as CSV files

Description

Creates a store that persists readings as plain CSV files (one per device) inside path. The most accessible option for collaborators who open data in a spreadsheet or a tool other than R. Datetimes are written as ISO 8601 UTC strings and re-parsed on read.

Usage

zc_store_csv(path)

Arguments

path

Directory to hold the .csv files. Created if it does not exist.

Value

A store object for use with zc_sync() and zc_store_read().

Examples

## Not run: 
store <- zc_store_csv("data/zentra")
zc_sync("z6-00930", store = store, start = Sys.Date() - 30)

## End(Not run)

Store readings in memory (session only)

Description

Creates a store that keeps readings in memory for the current R session. Data is not written to disk. Useful for experimentation or when another process (for example a database loader) will consume the returned data.

Usage

zc_store_memory()

Value

A store object for use with zc_sync() and zc_store_read().


Store readings as RDS files

Description

Creates a store that persists readings as native R .rds files (one per device) inside path. This is the most faithful option for RStudio project workflows: types (including POSIXct datetimes) round-trip exactly.

Usage

zc_store_rds(path)

Arguments

path

Directory to hold the .rds files. Created if it does not exist.

Value

A store object for use with zc_sync() and zc_store_read().

Examples

## Not run: 
store <- zc_store_rds("data/zentra")
zc_sync("z6-00930", store = store, start = Sys.Date() - 30)

## End(Not run)

Incrementally fetch and store readings

Description

zc_sync() is the workhorse for keeping a local record up to date. For each device it looks at what you already have, fetches only the readings newer than that, and appends them to your chosen store - so you can run it on a schedule (weekly, daily, or on file open) and always pull just the new data.

Usage

zc_sync(
  device_id = NULL,
  store = NULL,
  start = NULL,
  end = NULL,
  units = "metric",
  direction = "ascending",
  max_pages = Inf,
  max_active = 1L,
  quiet = FALSE,
  progress = NULL,
  key = NULL
)

Arguments

device_id

Device id, or a character vector of device ids. NULL (default) discovers and syncs every device your key can access.

store

Where to persist readings: a store from zc_store_rds(), zc_store_csv(), or zc_store_memory(). Pass NULL (default) for "return only" - readings are fetched and returned but not stored (useful when you load them into your own database).

start

Optional start of the window for devices with no stored data yet (a Date, POSIXct, epoch seconds, or ISO 8601 string). Ignored for devices that already have stored readings.

end

Optional end of the window. Defaults to now (the API's latest).

units

"metric" (default) or "imperial".

direction

Fetch order: "ascending" (default) or "descending".

max_pages

Maximum pages (calendar-month windows) to fetch per device. Defaults to Inf.

max_active

Maximum number of devices to fetch concurrently. Defaults to 1 (sequential). Because the readings rate limit is enforced per device, values above 1 fetch several devices at once, which can be dramatically faster for multi-device syncs. Ignored when syncing a single device.

quiet

If TRUE, suppress progress messages. Defaults to FALSE.

progress

Show a live per-device progress indicator while fetching? NULL (default) shows one in interactive sessions (unless quiet); set TRUE/FALSE to force it, or use options(zentraR.progress = FALSE).

key

Optional API key. Defaults to the key set with zc_set_key() or the ZENTRACLOUD_API_KEY environment variable.

Details

The window for each device is chosen automatically:

Pages are written to the store as they arrive, so an interruption (network drop, rate limit, cancelled run) never loses the pages already committed - the next run simply resumes where it left off.

Value

If store is NULL, a tidy readings tibble (the combined new readings across devices). Otherwise, a summary tibble with one row per device: device_id, rows_added, last_time (latest stored POSIXct), status ("ok" or "error"), and message.

Examples

## Not run: 
zc_set_key("my-secret-key")
store <- zc_store_csv("data/zentra")

# First run backfills from each device's first measurement (or `start`):
zc_sync("z6-00930", store = store, start = Sys.Date() - 30)

# Later runs fetch only what is new:
zc_sync("z6-00930", store = store)

# Sync every accessible device:
zc_sync(store = store)

# Return-only (no persistence), e.g. to load into your own database:
new_data <- zc_sync("z6-00930", start = Sys.Date() - 7)

## End(Not run)

These binaries (installable software) and packages are in development.
They may not be fully stable and should be used with caution. We make no claims about them.